English – Denon DN-M991R User Manual
Page 21
21
ENGLISH
(8) Starting Recording Automatically by Detecting the
Input Level
This function makes it possible to start recording by detecting the
input signal level.
1
Set the presettings.
Make the following settings, referring to “Preset
Functions and Operations” on Page 13.
16) RecLv (–**) dB
Recording starts when a signal with a level at or
above the set level is input.
17) RecOffset (*)
Recording begins this number of seconds before
the point where the set level is detected.
2
Set the recording pause mode.
Press the REC button.
3
Set the recording level start mode.
Press the LEVEL START button.
4
Start recording.
Press the PLAY/PAUSE button.
Recording starts when an input signal with a level at or
above the set level is detected.
NOTE: If the LEVEL START button is pressed while the
button is flashing, the recording level start mode is
canceled.
PLAY/PAUSE
PLAY/PAUSE
REC
ON/OFF
LEVEL
START
Lit
Flashing
(orange)
Flashing
Flashing
(orange)
Lit
Lit
When the LEVEL START button is pressed in the input
signal detection mode, recording starts immediately.
5
To stop recording:
Press the PLAY/PAUSE, STANDBY/CUE or STOP
(Keyboard) button.
PLAY/PAUSE
REC
ON/OFF
LEVEL
START
Lit
Lit
During recording
NOTE:
The auto track increment function and Auto Level Rec start
function may not work when recording analog signals containing
much noise. In this case lower the detection level to for
example –54 dB.
4
(continued)
Lit