beautypg.com

English – Denon DN-M991R User Manual

Page 21

background image

21

ENGLISH

(8) Starting Recording Automatically by Detecting the

Input Level

This function makes it possible to start recording by detecting the
input signal level.

1

Set the presettings.
Make the following settings, referring to “Preset
Functions and Operations” on Page 13.

16) RecLv (–**) dB

Recording starts when a signal with a level at or
above the set level is input.

17) RecOffset (*)

Recording begins this number of seconds before
the point where the set level is detected.

2

Set the recording pause mode.
Press the REC button.

3

Set the recording level start mode.
Press the LEVEL START button.

4

Start recording.
Press the PLAY/PAUSE button.

Recording starts when an input signal with a level at or
above the set level is detected.

NOTE: If the LEVEL START button is pressed while the

button is flashing, the recording level start mode is
canceled.

PLAY/PAUSE

PLAY/PAUSE

REC

ON/OFF

LEVEL
START

Lit

Flashing
(orange)

Flashing

Flashing
(orange)

Lit

Lit

When the LEVEL START button is pressed in the input
signal detection mode, recording starts immediately.

5

To stop recording:
Press the PLAY/PAUSE, STANDBY/CUE or STOP
(Keyboard) button.

PLAY/PAUSE

REC

ON/OFF

LEVEL
START

Lit

Lit

During recording

NOTE:
The auto track increment function and Auto Level Rec start
function may not work when recording analog signals containing
much noise. In this case lower the detection level to for
example –54 dB.

4

(continued)

Lit