Delta SS350LS User Manual
Page 16
16
CHANgINg BLADES
Disconnect machine from power source.
1. Remove table insert (A) Fig. 22, and release blade tension
by pulling tension lever (B) forward, as shown.
2. Push upper blade chuck locking lever (C) Fig. 23, to the
rear as shown. This will release the blade (D) from the
upper chuck (E).
3. Remove the dust collection cup (A) by rotating knob
(B) 90° as shown in Fig. 24. Slide dust cup out of the
guides (C) by pulling it toward the front.
NOTE: DO
NOT OPERATE THE UNIT WITH THE DUST CUP
REMOVED.
4. Push lower blade chuck locking lever (F) Fig. 25, to the
rear as shown. This will release the blade (g) from the
lower chuck (H).
Fig. 22
A
B
Fig. 23
E
C
D
Fig. 24
B
A
Fig. 25
F
G
H