beautypg.com

Table for the choice of the injectors, Lubrication of the gas taps – Kleenmaid FEG605X User Manual

Page 13

background image

13

TABLE FOR THE CHOICE OF THE INJECTORS

Natural gas

Propane gas

Test Point Pressure [kPa]

1.0

2.75

BURNER

Auxiliary (A)

0.85

3.60

0.53

3.60

Semi-rapid (SR)

1.12

6.30

0.70

6.30

Triple ring (TC)

1.65

13.30

0.95

11.90

Gas

Consumption

[MJ/h]

Injector

Orifice Dia.

[mm]

Gas

Consumption

[MJ/h]

Injector

Orifice Dia.

[mm]

LUBRICATION OF THE GAS TAPS

If the gas tap becomes stiff, it is necessary to dismantle it carefully and clean it with petroleum
spirit. Specialist high temperature resistant grease should be used to lubricate the tap before
replacing.
The operations must be carried out by an authorised person/service agent.

Figure 10