not recommended for users with beard or long hair extending to the
respiratory zone.
• Beware of a higher CO concentration in the air supply, which may
occur if the compressor does not work properly when lubricating oil
burns due to high temperatures.
• The supply air pressure must be within the range 300 – 1000 kPa.
• The supply pressure hoses may only be located in such places of the
workplace where they cannot be damaged.
• The maximum working pressure of the hose supplied to the
conditioner is 1000 kPa.
• Before connecting the unit to the air distribution, it is necessary to
check what medium is in the line and what is its quality. For the FA
Pressure units, it is necessary to provide breathable air according to
EN 12 021 standard.
• The FA Pressure unit can be combined with Beta 90 FreshAir or Delta
90 FreshAir head tops.
• Information on head parts are provided in the instructions for use of
the FreshAir head parts.
FA Pressure Conditioner
• Pressure hose for FA Pressure Conditioner is not antistatic and the
maximum temperature to which they are resistant without damage is
70 °C.
• The maximum length of the hose from the compressed air distribution
or FA Pressure Conditioner to the head unit must not exceed 10 m.
• The recommended temperature range of use ideally is 10 – 40 °C. At
lower temperatures, the use of the protective hood with air supply
may be unpleasant. The lowest allowable temperature for use of FA
Pressure is 10 °C.
NOTE! If the recommendations stated in this manual are ignored, the warranty
is automatically invalidated and the level of personal protection may not meet
the designated standards.