Preconditions for use, 4 manufactured by – Kemppi FreshAir Pressure Flow Control unit User Manual
Page 6

EN
errors or omissions. Kemppi reserves the right to change the specification of
the product described at any time without prior notice. Do not copy, record,
reproduce or transmit the contents of this guide without prior written
permission from Kemppi.
1.3
Requirements for compressed air supplied from
the compressor
• FA Pressure Conditioner can only be connected to a compressor which
supplies air at an oxygen concentration of 20 – 22 % vol.
• The carbon dioxide concentration must not exceed 500 ppm and the
carbon monoxide concentration must not exceed 15 ppm.
• The maximum concentration of water in the air may be 50 mg/m3 at
the rated pressure of 1 – 20 MPa. The humidity of the supplied air must
be controlled to prevent the unit from freezing.
1.4
Manufactured by
Manufactured for and on behalf of Kemppi Oy by:
CleanAir Ltd.
2.
PRECONDITIONS FOR USE
Before you can use the system correctly and safely, you must fully
understand all of the following precautions.
• It is forbidden to use the unit in explosive environments.
• The system may only be used in environments where the probability
of damaging the supply hose is small and the user’s movement is not
limited.
• If the unit is used in environments with high temperatures, the supply
hose must be resistant to such effects.
• During an extreme work load, the pressure in the hood may reach
negative values and the user may feel air deficiency. In such case the
protection of air passages is reduced.
• In the FreshAir system it is forbidden to use oxygen-enriched air or
oxygen. There is a risk of explosion.
• If another accessory apart from FreshAir (e.g. a spray gun) is connected
to the compressed air supply, the user must make sure that a sufficient
air flow to the hood is secured even at the maximum air consumption
by this accessory.
• Before every use of the unit, check that the air flow is higher than the
minimum value specified in the technical parameters.
• If the unit stops supplying air for any reason, the user must leave the
contaminated area immediately.
• The unit, in a combination with a welding helmet or a hard hat, is
6
FreshAir Pressure Flow Control / Conditioner