2 filter for fa pressure conditioner – Kemppi FreshAir Pressure Flow Control unit User Manual
Page 12
EN
6.2
Filter for FA Pressure Conditioner
The FA Pressure Conditioner contains a combined filter which removes oil
mist, smells and flavours from industrially produced compressed air.
NOTE: The filter does not remove CO and CO₂.
Read the instructions for use and replacement.
Replacing FA Pressure Conditioner filters:
x 6
1.
4.
2.
3.
1.
Unscrew the top part of the filter pressure container (6 screws).
2.
Remove the contaminated filter, wipe the inside of the container.
3.
Check the condition of the rubber seal in the top cover. If the seal is
damaged, replace it.
4.
Install a new filter on the container cover and screw it back.
5.
Check the container for leakage. If the container is not absolutely tight,
tighten all screws that fasten the top cover.
12
FreshAir Pressure Flow Control / Conditioner