beautypg.com

Vianetsintä, Troubleshooting, Fehlersuche – Kemppi Adaptive 150 User Manual

Page 19: Problemen oplossen, Résolution des pannes, Solución de problemas

background image

MinarcMig™ Adaptive 150

18

© Kemppi Oy 0550

EN

PROBLEM

CAUSE

The wire does not move

or wire feed entangles

Feed rolls, wire conduit or contact tips are

defective

• Check that feed rolls are not too tight or too

loose

• Check that the feed roll groove is not too

worn

• Check that the wire conduit is not blocked

• Check that there are no spatters on the

conduit tip and that the hole is not cramped

or worn loose

Main switch indicator

light does not switch on

The machine has no supply voltage

• Check supply voltage fuses

• Check supply voltage cable and plug

Machine welds badly

Welding outcome is influenced by several

factors

• Tarkista, että langansyöttö on tasaista

• Check the trimming settings of welding

power control and arc length

• Check that the earthing clamp is fixed

properly, fixing point is clean, and both

cable and its connections are undamaged

• Check the flow of shielding gas from the tip

of the welding gun

• Supply voltage is uneven, too low or too

high

Over-heating indicator

light switches on

The machine has over-heated

• Check that cooling air can flow without

obstructions

• Machine’s volume-capacity ratio has been

exceeded; wait for the indicator light to

switch off

• The supply voltage is too low or too high

5. TROUBLESHOOTING

If the machine’s malfunction can not be corrected with these measures, contact

the KEMPPI maintenance service.