TECHNICAL DATA
Protig 410
Working voltage (safety voltage)
50 VDC
Rated power
50 W
Max. load
60 % ED
400 A
100 % ED
310 A
Pressure endurance of gas hose
600 kPa max.
Connection of gas hose
snap connector
Welding cable connectors
DIX 70
Torch connection (adapter)
Multi-function
Operation temperature range
-20...+40 °C
Storage temperature range
-40...+60 °C
Temperature class
B (130 °C)
Degree of protection¹)
IP 34
Dimensions
length
615 mm
width
260 mm
height
400 mm
Weight
17 kg
1)
IP 34 means that the device is protected against water coming from any direction,
directly or splashing.
Control panels
Main operations of Protig 410 panels TL and TX are in enclosed table.
TL 6271265
TX 6271266
Spark ignition
yes
yes
Contact ignition
yes
yes
2 function / 4 function torch operation
yes
yes
Fusion point timer
--
yes
Pulsing
--
yes
Minilog operation
--
yes
Up-slope timer for current
yes
yes
Down-slope timer for current
yes
yes
Selectotig memory channels
--
yes
Current display (digital)
yes
yes
25
Pr
oT
ig 410 H
yundai / © Kemppi O
y / 1135