Technical data – Kemppi FastMig X 350 User Manual
Page 31
![background image](https://www.manualsdir.com/files/792584/content/doc031.png)
29
© Kemppi Oy / 1520
EN
Remote control unit R30 DataRemote
10 m
618542001
Remote control extension cable
10 m
6185481
Software installation device DataGun
6265023
NOTE!
WiseRoot+™ and WiseThin+™ welding processes are not available with SuperSnake sub
feeder.
10. TECHNICAL DATA
FastMig
X 350
X 450
Connection voltage
3~50/60 Hz
400 V, -15…+20 %
400 V, -15…+20 %
Rated power
60 % ED
22.1 kVA
80 % ED
16.0 kVA
100 % ED
15.3 kVA
16.0 kVA
Connection cable
HO7RN-F
4G6 (5 m)
4G6 (5 m)
Fuse
Delayed
35 A
35 A
Output 40 °C
60 % ED
450 A
80 % ED
350 A
100 % ED
330 A
350 A
Welding current and voltage range
MMA
15 A/20 V – 350 A/46 V 15 A/20 V – 450 A/46 V
MIG
20 A/12 V – 350 A/46 V 20 A/12 V – 450 A/46 V
Max. welding voltage MMA
46 V
46 V
Open circuit voltage
MMA
U
0
= 70 – 98 V
U
av
= 50 V
U
0
= 70 – 98 V
U
av
= 50 V
MIG/MAG/Pulse
U
0
= 80 – 98 V
U
0
= 80 – 98 V
Open circuit power
100 W
100 W
Power factor at max. current
0.85
0.88
Efficiency at 100 % ED
87 %
87 %
Operating temperature range
-20…+40 °C
-20…+40 °C
Storage temperature range
-40…+60 °C
-40…+60 °C
EMC class
A
A
Minimun short circuit power S
sc
of supply network*
5.5 MVA
5.5 MVA
Degree of protection
IP23S
IP23S
External dimensions
L x W x H
590 x 230 x 430 mm
590 x 230 x 430 mm
Weight
38 kg
38 kg
Voltage supply for auxiliary devices
50 V DC / 100 W
50 V DC / 100 W
Fuse (auxiliary device)
Delayed
6.3 A
6.3 A
Voltage supply for cooling unit
24V DC / 50 VA
24V DC / 50 VA
The minimum recommended generator output is 35 kVA.
* See section 2.2: Distribution network.