16 en – Kemppi FastMig X 350 User Manual
Page 18

FastMig X 350, X 450
16
EN
WISEROOT+
WFSpeed
1.5…8.0 m/min *
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min,
and by 0.1, when WFSpeed > 5 m/min
WFS-Max
Sets the limit for maximum WFSpeed
WFS-Min
Sets the limit for minimum WFSpeed
FineTuning
-9.0 … +9.0
Factory setting is 0.0
( = curve point)
Adjusts the base current of the curve (heat of the arc)
within certain limits.
FineTuningMax
-9.0 … +9.0
Step: 0.5
Sets the limit for maximum heat of the arc
FineTuningMin
-9.0 … +9.0
Step: 0.5
Sets the limit for minimum heat of the arc
* Different welding programs may further restrict the value range.
WISETHIN+
WFSpeed
0.7…25 m/min *
Sets the wire feed speed.
Changes by steps of 0.05, when WFSpeed < 5 m/min, and
by 0.1, when WFSpeed > 5 m/min
WFS-Max
Sets the limit for maximum WFSpeed
WFS-Min
Sets the limit for minimum WFSpeed
FineTuning
-9.0 … +9.0
Factory setting is 0.0
( = curve point)
Adjusts the arc voltage of the curve (arc length) within
certain limits
FineTuningMax
-9.0 … +9.0
Step: 0.5
Sets the limit for maximum arc length
FineTuningMin
-9.0 … +9.0
Step: 0.5
Sets the limit for minimum arc length
Dynamics
-9…+9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
MMA PROCESSES
Current
14…350/450 A
Welding current
CurrentMax
14…350/450 A
Set the limit for maximum current value
CurrentMin
14…350/450 A
Set the limit for minimum current value
ArcForce
-9…+9
Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
StartPower
-9…+9
Factory setting is 0 Adjusts arc ignition
CC PROCESS
Current
10…350/450 A
Welding current
CurrentMax
10…350/450 A
Set the limit for maximum current value
CurrentMin
10…350/450 A
Set the limit for minimum current value
Dynamics
-9…+9
Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
StartPower
-9…+9
Factory setting is 0 Adjusts arc ignition