Kemppi FastMig X 350 User Manual
Page 21

19
© Kemppi Oy / 1520
EN
SYSTEM CONFIG MENU
Water Cooling
ON, OFF, AUTO
Factory setting is AUTO
Water cooler control.
ON: Water cooler is always ON
OFF: Water cooler is always OFF
AUTO: Water cooler starts when welding
starts and turns off after a delay when
welding stops.
Cable Length
10…100 m
Step: 5
Factory setting is 10m
Welding cable loop length setting for
optimising arc control.
FineCalib
0V/100A…10V/100A Step: 0.1 V
Factory setting is 1.0V/100A
Fine Tuning Calibration Point. Compensation
for varying cable resistance.
System Clock
System Clock Settings
Device List
Shows a list of connected devices.
Info
Shows following information about the selected device.
Device name:
DevSW: Unit software version.
SysSW: System software version (base software version).
BootSW: Boot software version.
SW Item: Software item number (IFS code).
Serial: Device serial number.
Prog: Programmer name
Date: Programming time and date.
Restore Settings
User 1 (one of ten users) Channel:
Selected user can restore to his backup memory channels one by one.
Other users’ memory channels remain untouched.
Setup settings remain untouched.
User 1 (one of ten users) All Channels:
Selected user can restore all of his backup memory channels (0-9) at one time.
Other users’ memory channels remain untouched.
Setup settings remain untouched.
Restore To Factory:
All channels (of all users) are removed.
All users’ backup channels are removed.
All setup settings are set to defaults.
When MMA/CC/CV Mode is selected, the Restore Settings options are:
MMA/CC/CV Channel
MMA All channels
Restore To Factory
Licence Menu
Licence Code allows you to enter the licence code:
- Up and down arrows are used to select the code number position.
- Pulse encoder is used to select the code number (0–255) to be entered.
- Soft key button on the right is used to activate the licence number (after all numbers have been
entered). In case the code was wrong the earlier view will be displayed.
Licence Timers allows you to check the remaining time of the time-based Wise features.
WeldData Delay
1…60 s
Step: 1
Factory setting is 20 s.
Defines how long time the Weld Data is
displayed after welding ends.
Weld Data display is also turned off when
pulse encoder is turned or any button is
pressed.
Display Delay
1…20 s
Step: 1
Factory setting is 10
Defines how long time the information is
displayed (e.g. “Setting Saved” text). This is
not always the exact time.