3 use of the control panel – Kemppi KM 400 MVU User Manual
Page 9
EN
3.3
USE OF THE CONTROL PANEL
The control panel is used for controlling and monitoring the operation of the power source
and the wire feeder. The buttons are used for adjusting functions. The displays and indicators
reflect the operating modes of the machine.
GAS TEST
DYNAMICS
WIRE INCH
weld
data
V
A
m/min
4T
SETUP
2T
KM
W001319
LOCAL
REMOTE
P1
P2
P11
P9
P3
P4
P6
P5
P7
P12
P8
P10
3.3.1 Starting of the control panel
• When you start the power source with the main switch (S11), the control panel remains
in OFF mode and the wire feeder is not operational. The display shows the text ‘OFF’.
• When you depress the start button (1) for at least one second, the control panel starts.
The unit is now ready for welding and enters the mode that was active before the power
was cut off.
• You can also start the control panel by quickly pressing the welding gun switch three
times.
3.3.2 Displays
• When you are adjusting the machine settings, the control panel displays show adjustable
operation parameters, their values, and the units of measure.
• During welding, display 2 shows the welding current value that is currently in use, while
display 8 shows the welding voltage.
3.3.3 Control knobs
• The left-hand control knob (10) allows adjustment of the speed of wire feeding. The
selected speed is shown on the display on the left-hand side (2).
• The control knob on the right-hand side (11) allows you to adjust the welding voltage.
The selected voltage is shown on the right-hand display (8).
These adjusters are used also for selecting the values of the machine’s operational parameters,
such as the MIG mode and set-up features. A parameter for adjustment is selected with the
left-hand knob (10), while the value of the parameter is selected with the right-hand knob
(11).
7
FastM
ig KM 400 MVU / © Kemppi O
y / 1045