2.

INSTALLATION

2.1

POSITIONING OF THE MACHINE

Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other

impurities to enter the machines cooling air flow. Preferably site the machine above floor level;

for example on a suitable carriage unit.
Notes for positioning the machine

• The surface inclination should not exceed 15 degrees.

• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in

front of and behind the machine for cooling air to circulate.

• Protect the machine against heavy rain and direct sunshine.

NOTE!

The machine should not be operated in the rain as the protection class of the machine,

IP23S, allows for outside preserving and storage only.

NOTE!

Never aim metallic grinding spray/sparks towards the equipment.

2.2

DISTRIBUTION NETWORK

All regular electrical devices without special circuits generate harmonic currents into

distribution network. High rates of harmonic current may cause losses and disturbance to

some equipment.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc

is greater than or equal to 4.7 MVA at the interface point between the user’s supply and

the public supply network. It is the responsibility of the installer or user of the equipment

to ensure, by consultation with the distribution network operator if necessary, that the

equipment is connected only to a supply with a short-circuit power Ssc greater than or equal

to 4.7 MVA.

2.3

CONNECTION TO MAINS

FastMig KM power sources are connected to the 230-V or 400-V three-phase network using

the mains cable supplied with the machine.
The machine is equipped with a five-metre mains cable that does not have a plug. Before use,

check the mains cable and install a mains plug. If the cable does not comply with the local

electrical regulations, replace it with a compliant cable. See ’Technical specifications’.

NOTE!

The mains cable or plug may be installed or replaced by only an electrical contractor or

installer authorised to perform such operations.

Replacement of the mains cable

1.

Unscrew the mounting screws on the top and sides of the machine, and remove the case

by lifting it.

2.

Disconnect the phase leads from connectors L1, L2, and L3, and disconnect the

protective earth lead.

3.

Pass the cable to the machine through the inlet ring at the rear of the machine, and

secure the cable with a cable clamp.

4.

Connect the cable’s phase leads to connectors L1, L2, and L3.

5.

Connect the yellow-green protective earth lead to its connector.

NOTE!

Do not connect the zero lead if you are using a five-lead cable.

The table below lists the fuse sizes for 100% load in a 400-V three-phase network with 4 x 10-

mm² cable.

Voltage

Fuse, slow

Cable

400 V

35 A

H07RN-F 4G10 (10 mm²)

230 V

50 A

H07RN-F 4G10 (10 mm²)