3.3.4 Adjustment of MIG dynamics (arc force)
When you press button 3, you can adjust the MIG welding dynamics of the machine by means
of the right-hand knob, 11. The welding dynamics setting affects the properties of the welding
arc and the amount of spatter as follows:
• The value 0 is the recommended basic setting.
• Use values -1 … -9 if you want a softer arc and less spatter.
• Use values 1 … 9 if you want a rougher and more stable arc. This setting is useful when
you are using 100% CO2 shielding gas when welding steel.
3.3.5 Gas test
The gas test button (5) opens the gas valve without activating the wire feed or power source.
By default, gas flows for 20 seconds. The gas flow time remaining is shown on the display.
The right-hand knob (11) allows you to set the default gas flow time, between 10 and 60
seconds, and store the new default value in the machine’s memory. To abort the gas test, press
the start button or gun switch.
3.3.6 Wire feed test
When you press the Wire inch button, 6, the wire feeder engine starts but the gas valve does
not open and the power source is not activated. The default wire feed speed is 5 m/min, and
you can adjust the speed with the right-hand knob. When the button is released, the wire
feeding stops. The machine automatically goes back to the normal state after approximately
five seconds from release of the button or immediately when you press the start button.
3.3.7 Selection of liquid- or gas-cooled MIG gun
You can select a MIG gun cooled with liquid or gas by pressing buttons 3 and 5 simultaneously
and holding them down for at least one second.
• When the display reads ‘GAS’, you can use a gas-cooled MIG gun with the equipment.
• When the display reads ‘COOLEr’, you can use a liquid-cooled MIG gun with the
equipment.
You can change the gun selection by pressing buttons 3 and 5 again, as above. With a liquid-
cooled gun selected, the liquid cooling function is started when the power source is started
the next time.
3.3.8 Retrieval of weld data
The weld data function allows you to return to the welding current and voltage used during
the previous session, with the weld data feature. To use the feature, press buttons 5 and 7
simultaneously.
3.3.9 Selection of control panel
Button 12 allows you to switch control between the control panels in the power source and
wire feeder. The indicator shows which of the control panels is in use.
• When the ‘LOCAL’ light is on, the wire feeding speed and welding current are set using
knobs 10 and 11 of the power source control panel.
• When the ‘REMOTE’ light is on, the wire feed speed and welding current are set using the
control panel of the wire feeder. Knobs 10 and 11 of the power source are disabled in this
mode.
3.3.10 Setting of the MIG operating mode
Button 9 allows you to set the MIG welding gun to either two-sequence or four-sequence
mode. The indicator shows the mode selected.
• In two-sequence mode (2T), welding is started by pressing the gun switch and stopped
by releasing the switch.
• In four-sequence mode (4T), the following actions take place:
1.
When you press the gun switch, the shielding gas starts to flow.
2.
When you release the switch, welding starts.
3.
When you press the switch again, welding ends.
4.
When you release the switch again, the flow of the shielding gas ends.