Kemppi FastMig Pulse 350 User Manual
Page 18
EN
Crater 4T Timer
On or OFF
Factory setting is OFF
ON: if 4T is selected crater filling will last
at least time that has been ad-justed by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected crater filling will last as
long as trigger is pressed.
Creep Start
10 – 99%
1% steps. OFF, CURVE (OFF =
100%)
Factory setting is CURVE (Creep Start value
comes from Welding program).
ADVANCED FUNCTIONS
WisePenet
ON or OFF
Penetration control selection
Penet%(123A)
-30 ... +30 %
Factory setting: 0 %
Wise penetration percent setting. Set
penetration Current.
WiseFusion
ON or OFF
WiseFusion selection
WiseFusion%
10 – 60 % or
CURVE
Factory setting is CURVE
When WISE FUSION is ON it controls the
amount of short circuits in the arc. The
lower the value there will be less short
circuits in the arc. The higher the value
there will be more short circuits in the arc.
MatchLog Menu
—> MinilogLevel
-99 ... +125
Factory setting: 20 %
Set the “MiniLog level”
SYSTEM CONFIG MENU
Water Cooling
Water Cooler control:
OFF / AUTO / ON.
Factory setting: AUTO
OFF: Water Cooler always OFF.
AUTO: Water Cooler automatic control
ON. Water Cooler starts when welding
starts and is turned off after a delay when
welding stops.
ON: Water Cooler is always ON.
Cable Length
Cable length: 10m –
100m, 5m steps.
Factory Setting: 10m
Welding cable loop length setting for
optimising arc control.
FineCalib
Fine Tuning
Calibration Point:
0.0V/100A –
10V/100A,
0,1V steps.
Factory Setting: 1.0V/100A
Compensation for varying cable resistance.
System Clock
System Clock Settings
Device
Information
System Device information:
DevSW: Unit Software Version.
SysSW: System Software Version (Base software version).
BootSW: Boot Software Version.
SW Item: Software Item Number (IFS number).
Serial: Device Serial number.
Prog: Programmer name
Date: Programming date.
FastMig Pulse 350, 450
16