beautypg.com

Kemppi FastMig Pulse 350 User Manual

Page 16

background image

EN

DOUBLE PULSE MIG

WFSpeed

0.7 – 25 m/min *

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

FineTuning

-9.0 ... +9.0

Factory setting is 0.0
( = curve point)
0.5 steps

Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.

FineTuningMax

-9.0 ... +9.0

0.5 steps

Set the limit for maximum arc length

FineTuningMin

-9.0 ... +9.0

0.5 steps

Set the limit for minimum arc length

Dynamics

-9 ... +9

Factory setting is 0

Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.

Pulse Current

-10% ... +15%

Factory setting
is 0%

Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%

DPulseAmp

0.1 – 3.0 m/min

Factory setting is
CURVE

Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding program.

DPulseFreq

0.4 – 8.0 Hz

Factory setting is
CURVE

Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding program.

WISEROOT / WISETHIN

WFSpeed

0.7 – 14 m/min *

0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min

WFS-Max

Set the limit for maximum WFSpeed

WFS-Min

Set the limit for minimum WFSpeed

BaseCurrent

-50 ... +50

Adjusts the base current of the curve – the arc length –
within certain limits.

BaseCurrentMax

-50 ... +50

1% steps

Set the limit for maximum “arc length”

BaseCurrentMin

-50 ... +50

1% steps

Set the limit for minimum “arc length”

FormingPulse

-30 ... +30

Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.

FormingPulseMax

-30 ... +30

1% steps

Set the limit for maximum forming pulse current

FormingPulseMin

-30 ... +30

1% steps

Set the limit for minimum forming pulse current

StartTime

-9 ... +9

Factory setting is 0

Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.

StartVoltage

-30 ... +30

Factory setting is 0

Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.

* Different welding programs may further restrict the value range further.

MMA PROCESSES

Current

14 – 350A/450A

Welding current

CurrentMax

14 – 350A/450A

Set the limit for maximum current value

CurrentMin

14 – 350A/450A

Set the limit for minimum current value

ArcForce

-9 ... +9

Factory setting is 0 Controls the short circuit behaviour of the arc. The

lower the value the softer the arc is. The higher the
value the rougher the arc is.

StartPower

-9 ... +9

Factory setting is 0 Adjusts arc ignition

FastMig Pulse 350, 450

14

This manual is related to the following products: