Kemppi FastMig Pulse 350 User Manual
Page 16
EN
DOUBLE PULSE MIG
WFSpeed
0.7 – 25 m/min *
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0
Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9.0 ... +9.0
0.5 steps
Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0
0.5 steps
Set the limit for minimum arc length
Dynamics
-9 ... +9
Factory setting is 0
Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15%
Factory setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%
DPulseAmp
0.1 – 3.0 m/min
Factory setting is
CURVE
Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding program.
DPulseFreq
0.4 – 8.0 Hz
Factory setting is
CURVE
Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding program.
WISEROOT / WISETHIN
WFSpeed
0.7 – 14 m/min *
0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
BaseCurrent
-50 ... +50
Adjusts the base current of the curve – the arc length –
within certain limits.
BaseCurrentMax
-50 ... +50
1% steps
Set the limit for maximum “arc length”
BaseCurrentMin
-50 ... +50
1% steps
Set the limit for minimum “arc length”
FormingPulse
-30 ... +30
Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
FormingPulseMax
-30 ... +30
1% steps
Set the limit for maximum forming pulse current
FormingPulseMin
-30 ... +30
1% steps
Set the limit for minimum forming pulse current
StartTime
-9 ... +9
Factory setting is 0
Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.
StartVoltage
-30 ... +30
Factory setting is 0
Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
* Different welding programs may further restrict the value range further.
MMA PROCESSES
Current
14 – 350A/450A
Welding current
CurrentMax
14 – 350A/450A
Set the limit for maximum current value
CurrentMin
14 – 350A/450A
Set the limit for minimum current value
ArcForce
-9 ... +9
Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
StartPower
-9 ... +9
Factory setting is 0 Adjusts arc ignition
FastMig Pulse 350, 450
14