Weld Data

Check out the values of the last weld

System Config Menu

Show device configuration and information

Language

Select your menu language

Select Feeder (WF#)

Select another parallel wire feeder as a setup target

MMA On/Off

Activate MMA welding

4. Adjustment knob

Turn the knob to change the value of the selected parameter. In MMA mode when the

panel is in default initial view (channel information), knob can be used to adjust current.

5. Menu browsing buttons

Use up and down arrows to move the selection up and down in the menu structure. In

MMA mode when the panel is in default initial view (channel information), Up/Down

buttons can be used to adjust Arcforce.

6. Menu shortcut buttons

F1 (CHANNEL INFO) Displays the basic data recorded to the displayed channel. Pressing

F1 multiple times gives more information of the selected memory channel. Keeping F1

pressed while turning the machine ON restores the menu language to English.

F2 (USER) Browses and selects users: 1…10, Administrator. When MMA is selected, only

Administrator is allowed.

F3 (WF#) Selects another wire feeder as a setup target. Panel allows selecting only those

WF numbers that are found connected on the system.

NOTE!

FastMig Pulse allows up to 4 wire feeders to be connected to one power source. Only one

wire feeder can be active at a time and must be selected before it will operate.

7. LCD menu display
8. Soft key buttons for menu selection

Use these buttons to select menu items. Their functions depend on selected menu items.

The function is shown on the display.

4.2 Using the menus

4.2.1 Selecting the interface language

The default menu language is English. If you want to select another menu language, do the

following:

1.

Connect the mains power and switch on the power source at the main switch.

• If this is the initial system activation (if SYSTEM OFF text is in the display), you may

need to press and hold the POWER ON button in the top left corner of the P 65 control

panel. Hold the button down for 5 seconds.

2.

Press the MENU button to display the main menu, which includes 7 menu items.

• You can move around in the menu list by pressing the up and down arrow buttons.

• As you browse the menu item list, the currently selected item is shown at the bottom

of the display, marked as 1/7, 2/7, 3/7 etc.

• The selected menu item is marked with a black arrow-shaped cursor.

3.

Browse to the menu item LANGUAGE (5/7) and press the SELECT soft key button.

4.

Browse to your language and press the SELECT/SAVE soft key button. Your language

choice is now confirmed and will remain selected unless you change it later.

4.2.2 About memory channels

You can have several setups of welding parameter values for use in various welding

applications. These setups (or welding jobs) are stored on a memory chip in the wire feeder.
Up to 10 user profiles can be defined in one FastMig Pulse unit, and each of them are assigned

up to 10 memory channels. So, you have maximum of 100 memory channels to store your

frequently used welding jobs. In addition to them, there are 10 memory channels available for

MMA use.

11

© Kemppi Oy / 1515