4.3.2 Welding functions

OTHER PROCESSES

2T/4T

2T, 4T, MATCHLOG
or USER

Factory setting is USER =>
USER can freely choose the
switching logic

Set switching logic

HotStart

ON, OFF or USER

Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF

HotStartLevel

-50 ... +100 %

1 % steps. Factory setting 40%

Hot 2T Time

0.0 – 9.9 s

0.1 s steps. Factory setting 1.2 s

CraterFill

ON, OFF, USER

Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF

CraterStart

10 – 250%

Factory setting is 100%

Set the level of the curve where the crater
filling will start

CraterFillEnd

10 – 250 %, not
higher than start

1 % steps. Factory setting 30% Set the level of the curve where the crater

filling will end.

CraterTime

0.0 – 10.0 s

0.1 s steps. Factory setting 1.0 s CrateFill Slope Time

Crater 4T Timer

On or OFF

Factory setting is OFF

ON: if 4T is selected crater filling will last
at least time that has been ad-justed by
CraterTime or as long as trigger is pressed.
OFF: if 4T is selected crater filling will last as
long as trigger is pressed.

Creep Start

10 – 99%

1% steps. OFF, CURVE
(OFF = 100%)

Factory setting is CURVE (Creep Start value
comes from Welding program).

StartPower

-9 ... +9

Factory setting is 0

Adjusts arc ignition

WISEROOT / WISETHIN

2T/4T

2T, 4T, MATCHLOG
or USER

Factory setting is USER =>
USER can freely choose the
switching logic

Set switching logic

HotStart

ON, OFF or USER

Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF

HotStartLevel

-50 ... +100 %

1 % steps. Factory setting 40%

Hot 2T Time

0.0 – 9.9 s

0.1 s steps. Factory setting
1.2 s

CraterFill

ON, OFF, USER

Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF

CraterStart

10 – 250%

Factory setting is 100%

Set the level of the curve where the crater
filling will start.

CraterFillEnd

10 – 250%, not
higher than start

1 % steps. Factory setting 30%

CraterTime

0.0 – 10.0 s

0.1 s steps. Factory setting
1. 0 s