Ivoclar Vivadent P310 - Short Instructions User Manual
Page 5
Establishing the connections
Connect the cables of the furnace head with the furnace base.
Proceed as follows:
- Connect vacuum hose (6).
- Insert the thermocouple plug (7). (Make sure that the polarity of
the plug is correct.)
- Insert the heater plug (8).
Insert the heater plug into the specified connector. Secure the heater plug by
rotating it by 45°.
Closing the protective cover
When all cables are correctly connected to the base, close the
cover (9) to protect the connections until you feel it click into place.
Mounting the connection cover
The connection cover (10) can now be mounted and secured with the
screws.
The furnace may only be used with the protective cover closed and
the connection cover mounted!
Establishing additional connections
Power connection
Make sure that the voltage indicated on the rating plate complies with the
local power supply. Subsequently, connect the power cord (11) with the
power socket of the Programat (12).
Connecting the vacuum pump
Connect the vacuum pump plug (13) with the vacuum pump socket (14). We
recommend using only the VP4 vacuum pump from Ivoclar Vivadent, since
this pump is especially coordinated with the furnace. If other pumps are used,
please observe and do not exceed the indicated maximum power consumption.