Limited warranty, Specifications, Troubleshooting – Infloor Thermostat 29053 V1 User Manual
Page 2: Operation

Limited Warranty
This limited warranty does not cover shipping costs. Nor does it cover a
product subjected to misuse or accidental damage. This warranty does not
cover the cost of installation, diagnosis, removal or reinstallation, or any
material costs or loss of use.
This limited warranty is in lieu of all other warranties, obligations, or liabilities
expressed or implied by the company. In no event shall Infloor Sales & Service
SW be liable for consequential or incidental damages resulting from installa-
tion of this product. Some states or provinces do not allow limitations on how
long an implied warranty lasts, or the exclusion or limitation of incidental or
consequential damages, so the above exclusions or limitations may not apply
to you. This warranty gives you specific legal rights and you may also have
other rights that vary from state to state.
Mount the Relay
1. Carefully fold and press the wires
back into the electrical box. Do not
use the control to push them in, as this
may cause connections to loosen and
possible failure.
2. Secure the Power Module into the box
with the mounting screws provided.
3. Carefully snap the Front Module onto
the Power Module.
4. Tighten the screw.
5. Switch on the power at the main
circuit panel.
NOTE to contractors: After installing
the thermostat, be sure to:
a. Switch on the relay(s)
b. Do a Quick Setup of the master thermostat (see instructions for your
Infloor
thermostat)
c. Temporarily override the thermostat setpoint temperature, making
sure it signals this Relay to begin heating for a few minutes
d. Test the GFCI
(section 3)
5. Specifications
Power Supply
120/240 VAC, 50/60 Hz
Maximum Load
15 amps, resistive
Maximum Power
1800 watts at 120 VAC
3600 watts at 240 VAC
GFCI
Class A (5 milliamp trip)
Storage Temp
0 °F to 120 °F (0 °C to 49 °C)
ETL Listing
Control No. 3037530
4. Troubleshooting
Problem
Solution
Relay works (has green
light) but no heat from
the system.
1. Check signal wire connections at Relay and master
thermostat.
2. Check power wiring connections.
3. If GFCI is tripped, reset Relay.
4. Check resistances on floor warming system. See
manual for system.
No lights showing.
1. Check power wiring connections.
2. Check circuit breaker or other protection “upstream” of
thermostat.
GFCI is tripped.
1. Check wiring connections.
2. Reset Relay by switching off/on.
3. Check resistances on floor warming system. See
manual for system.
3. Operation
On/Off Switch
Your Infloor
Relay should be turned off when
it is first installed.
1. Slide the on/off switch to the upper position,
turning the control on. A green light will show
on the front if power is applied. If the light is
amber, it indicates power is applied to the floor
warming system.
2. To turn the control off anytime, slide the
on/off switch to the lower position. No heating
will occur.
Test the GFCI
There is a GFCI (Ground Fault Circuit Interrupter) inside the Infloor
Relay. It
is designed to help protect people from possible electrical shock if the floor
warming system has been damaged.
To make sure the GFCI is operating, test it after it is installed and once each
month:
1. Make sure the Relay is heating, showing the amber light on the front. You
may need to increase the setpoint temporarily on the master thermostat.
2. Press the GFCI Test button on the side of the control. A red light should
show next to the GFCI Test button. You should also hear a click, indicating
power has been removed from the floor warming system. If any of these indi-
cators fail, turn off the Relay and replace it. Do not continue to use.
3. To reset the GFCI, slide the On/Off switch off and back on. If the GFCI does
not reset, turn the control off and go to section “4 Troubleshooting” for help.
on/off
Infloor Sales & Service SW warrents this control (the product) to be free from
defects in material and workmanship for a period of (2) years from the date of
original purchase from authorized dealers. During this period, Infloor Sales &
Service SW will replace the product or refund the original cost of the
procduct or refund the original cost of the product at Infloor Sales & Service
option, without charge, if the product is proven defective in normal use.
Please return the control to your distributor to begin the warranty process.