beautypg.com

Thermal considerations, Thermal curves, Thermal testing setup – Delta Electronics Delphi Series E24SR User Manual

Page 10: Thermal derating

background image

DS_E24SR05012_01032008


10

THERMAL CONSIDERATIONS


Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.


Thermal Testing Setup

Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.

The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

12.7 (0.5”)

MODULE

AIR FLOW

50.8 (2.0”)

FACING PWB

PWB

AIR VELOCITY
AND AMBIENT

TEMPERATURE

MEASURED BELOW

THE MODULE

Figure 20:

Wind tunnel test setup

Thermal Derating


Heat can be removed by increasing airflow over the module.
To enhance system reliability, the power module should
always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be affected.

THERMAL CURVES

Figure 21:

Hot spot temperature measured point

The allowed maximum hot spot temperature is defined at

118

E24SR05012(Standard) Output Current vs. Ambient Temperature and Air Velocity

@Vin = 24V (Transverse Orientation)

0

2

4

6

8

10

12

25

30

35

40

45

50

55

60

65

70

75

80

85

Ambient Temperature (℃)

Output Current(A)

Natural

Convection

100LFM

200LFM

Figure 22:

Output current vs. ambient temperature and air velocity

@V

in

=24V (Transverse Orientation)