Specifications

2011-06-01

45

7.2

Interconnect Cable

Pos: 47 /806-IHSE/Technische Daten/Verbindungskabel/Glasfaser @ 6\mod_1304498483633_6.doc @ 50597 @ 3

7.2.1

Fiber

A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Switches or Routers, is not allowed.

Type of Interconnect Cable

(Cable notations according to VDE)

Type of cable

Specifications

Multi-Mode 50μm

One fiber 50μm

I-V(ZN)H 2G50 (in-house patch cable)

I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)

Multi-Mode 62.5μm

One fiber 62.5μm

I-V(ZN)HH 2G62.5 (in-house breakout
cable)

A/DQ(ZN)B2Y

4G62.5

(outdoor cable,

with protection against rodents)

Maximum Acceptable Cable Length

Type of cable

Maximum Acceptable Cable Length

Multi-Mode 50μm (OM3) 1,000 m (3,280 ft)
Multi-Mode 50μm

400 m (1,300 ft)

Multi-Mode 62.5μm

200 m (650 ft)

Pos: 50 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_258.doc @ 43738 @

Type of Connector

Connector

SC Connector

Pos: 48 /806-IHSE/Technische Daten/Getestete Peripherie/UEB_Getestete Peripherie @ 5\mod_1278578478761_6.doc @ 42242 @ 2