Hypertherm Powermax125 Service Manua User Manual
Page 43

Powermax125 Service Manual 808070
43
3 – Basic System Operations
Fault – The system stops cutting. If you cannot correct the problem and restart the system,
contact your distributor or Hypertherm Technical Service.
Error – The system requires service. Contact your distributor or Hypertherm Technical Service.
Torch cap sensor – Indicates that the consumables are loose, improperly installed, or missing.
Turn OFF the power, properly install the consumables, and turn ON the system again to reset the
power supply.
Temperature – Indicates that the temperature of the power supply power module is outside the
acceptable operating range.
Gas – Indicates that the gas is disconnected from the rear of the power supply or there is a
problem with the gas supply.
Internal Serial Communications Interface – Indicates a problem with communications
between the control board and the DSP board.