Machine interface pinout, Figure 2 – Hypertherm Powermax125 Service Manua User Manual
Page 102
![background image](https://www.manualsdir.com/files/789815/content/doc102.png)
102
Powermax125 Service Manual 808070
7 – Mechanized Cutting
Machine interface pinout
Figure 2 – Connector sockets
Table 11 when connecting the power supply to a torch height controller or CNC controller with a machine
interface cable.
Table 11 – Machine interface cable signals
Signal
Type
Notes
Connector sockets
External cable wires
Start (start
plasma)
Input
Normally open.
18 VDC open circuit voltage at
START terminals. Requires dry
contact closure to activate.
3, 4
Green, black
Transfer (start
machine motion)
Output
Normally open. Dry contact closure
when the arc transfers.
120 VAC/1 A maximum at the
machine interface relay.
12, 14
Red, black
Ground
Ground
13
Voltage divider
Output
Divided arc signal of 20:1, 21.1:1,
30:1, 40:1, 50:1 (provides a
maximum of 16 V).
5 (-), 6 (+)
Black (-), white (+)
3
4
5
6
12
13
14