MAINTENANCE AND PARTS
5-2
RT60 / RT60M
Operator Manual
0
Routine Maintenance
Each Use
Check gas pressure.
Replace damaged power
cord or plug.
Replace damaged
torch lead.
Check pressure hose, filter
element, and connections
for leaks.
Clean the inside of
the power supply
with air pressure or
vacuum.
Replace damaged labels.
Check torch cap-on safety switch: observe that
red fault LED and yellow torch cap LED illuminate
when cap is loosened.
Check consumables for wear
and proper installation.
Check trigger for damage. Check torch
body for cracks or exposed wires.
Each Week
6 Months
3 Months
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
See Section 1 of the Operator Manual for additional safety precautions.