Torch Installation
ቢ
Turn OFF power.
ባ
Remove power cord from power receptacle.
ቤ
1. Align the connector key-way on the torch lead with the connector receptacle on the power supply and
push in until the pins seat.
2. Before tightening, turn the connector securing ring 1/4 turn to the left to ensure that the securing ring
threads and the connector receptacle threads are aligned.
3. Turn the securing ring to the right to tighten.
4. Clean the top of the power supply and apply the new operation label over the existing label.
Receptacle
Securing ring
Operation label
(Part No. 110522)
Key-way
Note: If the receptacle is missing or damaged it should be replaced with a new receptacle.
Part Number
Description
028522
MAX42 receptacle
028523
MAX43 receptacle
029962
Powermax800 receptacle
128493
Powermax600 receptacle
129325
Powermax900 receptacle