Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual
Page 98

Torch SeTup
3-50
powermax
65/85 Service Manual
65A Unshielded
Air flow rate - slpm/scfh
Aluminum
Hot
160 / 340
Cold
220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.1
7750
123
11300
122
3
0.2
6550
124
9500
123
4
0.5
5400
125
7640
124
6
3000
127
3900
126
8
0.7
1800
130
2460
127
10
6.0
300
0.7
1100
133
1640
129
12
Edge Start
900
135
1250
133
16
600
139
700
136
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
1/16 in
0.08
0.20
250
0.1
325
122
476
122
1/8 in
250
124
360
123
3/16 in
175
125
245
124
1/4 in
0.5
100
127
128
126
3/8 in
0.24
300
0.7
45
132
68
128
1/2 in
Edge Start
32
136
44
134
5/8 in
24
138
28
136