TroubleshooTing and sysTem TesTs

5-22

powermax

65/85

Service Manual

To move the field selector (*) between fields, press the current/gas mode selector. The asterisk indicates the selected

field. You can alter the I, C, B, P, and G fields by turning the adjustment knob.

To toggle between (I) Current set/read and (P) Pressure set/read, press the automatic/manual mode selector. The LED

is illuminated when the Pressure set/read field is selected.

To exit the service screen, simultaneously press the automatic/manual and current/gas mode selectors. The operator

screen displays.

Important fault icons

One of the following fault icons may appear on the LCD display in operator mode:

Warning

The system continues to operate.

Fault

The system stops cutting and is able to recover when the fault is cleared.

Error

The system needs service.

Performing a cold restart

Sometimes a “cold restart” clears the fault. When a cold restart is recommended in one of the Solutions below, do the

following:
1. Power OFF the machine.
2. Wait 20 seconds or until the red LED near the top of the DSP board blinks.
3. Power ON the machine.