Aluminum, Above water, 3" under water – Hypertherm HT200LHF-200 Volt HySpeed User Manual
Page 78: 200 amps • n, Plasma / air shield
![background image](https://www.manualsdir.com/files/789766/content/doc078.png)
OPERATION
HySpeed HT2000LHF
Instruction Manual
4-25
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (Air)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(N
2
%)
(N
2
%)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (Air)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(N
2
%)
(N
2
%)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
3/16
5
50
60
60
1/8
3
1/4
6
130
180
4570
0.5
1/4
6
(66.4
(79.6
(270
1/8
3
1/4
6
135
160
4060
1.0
3/8
10
SCFH)
SCFH)
SCFH)
1/8
3
1/4
6
135
120
3050
1.5
1/2
12
1/8
3
1/4
6
140
80
2030
2.0
5/8
15
.157
4
.314
8
140
70
1780
2.0
3/4
20
3/16
5
3/8
10
150
50
1270
2.5
7/8
22
1/4
6
1/2
12
160
35
890
2.5
1
25
1/4
6
165
25
635
1-1/4
32
`
1/4
6
175
20
510
1-1/2
38
1/4
6
185
10
250
Aluminum
200 amps • N
2
Plasma / Air Shield
This gas combination is used when cut edge quality is less important. Electrode life is extended when this
combination is used.
Notes:
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
Production cutting above 7/8" (22 mm) not recommended
Above Water
3/16
5
50
60
70
1/8
3
1/4
6
135
170
4350
0.5
1/4
6
(66.4
(79.6
(280
1/8
3
1/4
6
140
140
3650
1.0
3/8
10
SCFH)
SCFH)
SCFH)
1/8
3
1/4
6
140
100
2600
1.5
1/2
12
1/8
3
1/4
6
145
65
1620
2.0
5/8
15
.157
4
.314
8
145
55
1350
2.5
3/4
20
3/16
5
3/8
10
155
35
890
3.0
7/8
22
1/4
6
1/2
12
165
25
620
3.0
3" Under Water
020424
Shield
120837
Retaining cap
020608
Nozzle
020607
Swirl ring
020415
Electrode
7