Hypertherm HT200LHF-200 Volt HySpeed User Manual
Page 162

APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING
a-2
HySpeed HT2000LHF
Instruction Manual
6
Argon-Hydrogen supply to Argon-Hydrogen Manifold
• Attach one end of the supply hose to the argon-hydrogen supply tank regulator, and attach the other end to
the argon-hydrogen supply hose connection on the manifold. (Figure a-2)
Figure a-2
Argon-Hydrogen Manifold Connection Points
Cable Connection Point
Plasma Gas
Torch Lead
Connection
Argon-Hydrogen
Supply Hose
Connection
Argon-Hydrogen Cable – Argon-Hydrogen Manifold to Power Supply
1. Connect the receptacle end of the argon-hydrogen cable to the cable connection point on the argon-
hydrogen manifold. (Figure a-2)
2. Connect the other end of the cable to TB4 (smaller terminal strip on the inside rear panel of the power
supply). Match up wires 102, 103, 13 and 14 to wires already connected to the strip. Connect the two
shield wires to points labeled as PE (protective earth).
Part No.
Length
023660
15 ft (4.6 m)
023661
25 ft (7.6 m)
023662
50 ft (15 m)
023663
75 ft (23 m)
023664
100 ft (30 m)
023665
150 ft (46 m)
13
13
14X1
13
14
etc.
14x1
TB4
Color
Signal
1
13
Red
PS1 / Plasma
2
14
Black
PS1 / Plasma
12
Shield
Shield
3
102
Green
SV5 / Plasma Off
4
103
Black
SV5 / Plasma Off
9
Shield
Shield