Hypertherm HT200LHF-200 Volt HySpeed User Manual
Page 164
APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING
a-4
HySpeed HT2000LHF
Instruction Manual
6
Figure a-5
Nitrogen Supply to Gas Console
Nitrogen supply to Gas Console
• Connect the nitrogen supply to the shield connection at the rear of the gas console. (Figure a-5)
Ni
trogen
2WRENCHES
4. Connect the left-hand threaded connector
015049 to the torch plasma gas hose.
5. Attach one end of the argon-hydrogen
plasma gas torch lead to the plasma gas
torch lead connection located on the front
of the argon-hydrogen manifold.
(Figure a-4)
6. Attach the other end of the argon-
hydrogen plasma gas torch lead to the
015049 connector.
Plasma gas torch lead
connection
015049
connector
Torch
plasma gas
hose
Argon-hydrogen plasma gas
torch lead
Figure a-4
Converting the HT2000LHF Torch for Argon-Hydrogen Cutting – 2 of 2