Connecting the power (continued) – Hypertherm HT200LHF-200 Volt HySpeed User Manual
Page 39

INSTALLATION
3-6
HySpeed HT2000LHF
Instruction Manual
7
1. Insert the power cable through the strain relief at the lower left rear of the power supply. Connect the power
cable leads to
TB1
located at the center wall, right side.
2. Connect the power leads to the
L1
,
L2
, and
L3
terminals of
TB1.
See Fig. 3-1.
3. Connect the ground lead as shown.
Figure 3-1
Power Cable Connections
Ground lead
To connect the power
cable to the 400V CE
power supplies refer to
the appendix section.
WARNING
There is line voltage at the contactor if the line disconnect switch is in the ON position, even if the
ON (1) pushbutton on the power supply has not been pressed. As a common safety practice,
ALWAYS verify that the line disconnect switch is in the OFF position before installing, disconnecting
or servicing in this area.
Connecting the Power (continued)