Cut-cycle time – Hypertherm HPR130 Auto Gas Preventive Maintenance Program User Manual
Page 24
24
HPR130 Auto Gas Instruction Manual 808580
Preventive Maintenance Program
Cut-cycle time
When the cut-cycle is very short, relays operate more frequently. The system also pierces more frequently. Examples of
this type of cycle are when you cut many small holes or make markings for numbers and letters. These types of operations
can cause the following problems:
Increase wear on pilot arc relay contact pads
Increase wear on the starting components, such as the high-frequency transformer and the high-frequency ignition
board
Increase misfires and error codes (020 or 021)
If your cut-cycle is short, you can replace the following components more frequently.
Description
Part number
Pilot arc relay
003149
Contactor
003249
HPR quick-disconnect torch
220162
High-frequency transformer
129854
High-frequency ignition board (PCB)
041817
- HPR130 Manual Gas Preventive Maintenance Program HPR130XD Auto Gas Preventive Maintenance Program Rev.1 HPR130XD Manual Gas Preventive Maintenance Program Rev.1 HPR260 Auto Gas HPR260XD Auto Gas Preventive Maintenance Program Rev.1 HPR260XD Manual Gas Preventive Maintenance Program Rev.1 HPR400XD Auto Gas Preventive Maintenance Program Rev.1 HPR800XD Auto Gas Preventive Maintenance Program Rev.1 HPR400XD Manual Gas Preventive Maintenance Program Rev.1 HPR800XD Manual Gas Preventive Maintenance Program Rev.1