Weekly
Examine hoses and torch leads
1. Examine all air hoses, coolant hoses, and torch leads for:
Scrapes, cuts, or holes
Chemical spills or burns
Kinks or bends
2. Replace any hoses or leads that have damage.
Part numbers for HPR130 Auto Gas cables and leads on page 26 for lengths and part numbers.
Do tests for gas leaks
For more information, see
Gas leak tests in the Maintenance section of your system’s instruction manual.
Do the following gas system tests:
Inlet Leak test
System Leak test
Proportional valve test – Make sure that you use the 130 A O
2
/Air consumables and that you select the 30 A O
2
/O
2
plasma process.
Do a check of the coolant flow
Find the flow rate shown on the CNC’s diagnostic screen. Record the coolant flow.
If the information on the CNC indicates a problem with the coolant flow, do the tests described in
Coolant flow tests in
the
Maintenance section of your system’s instruction manual.
If the flow rate is below 2.9 L/min (0.75 g/min), contact your maintenance department to service the coolant system.
Do a check of the coolant level
Make sure that the tank is full to the neck with coolant:
1. Open the cover of the coolant tank on the outside of the enclosure.
2. If the level of the coolant is below the top of the tank, add coolant (028872) to the neck of the
tank.
3. Record the number of gallons your system requires in Coolant requirements on page 30.
- HPR130 Manual Gas Preventive Maintenance Program HPR130XD Auto Gas Preventive Maintenance Program Rev.1 HPR130XD Manual Gas Preventive Maintenance Program Rev.1 HPR260 Auto Gas HPR260XD Auto Gas Preventive Maintenance Program Rev.1 HPR260XD Manual Gas Preventive Maintenance Program Rev.1 HPR400XD Auto Gas Preventive Maintenance Program Rev.1 HPR800XD Auto Gas Preventive Maintenance Program Rev.1 HPR400XD Manual Gas Preventive Maintenance Program Rev.1 HPR800XD Manual Gas Preventive Maintenance Program Rev.1