Preventive Maintenance Program
Consumable use
If you let consumables reach complete failure, they can melt. Copper pieces can then break off and go into the coolant. In
the coolant, these pieces can cause the following problems:
Decrease coolant flow
Increase coolant flow errors (093)
Cause damage to the consumables
Cause coolant to leak at the check valve when you change the consumables
Cause inaccurate coolant flow readings
Decrease the life of the coolant pump
Decrease the life of the check valve
When you do maintenance, examine the coolant filter for copper pieces. If you find copper pieces in the coolant filter,
replace both the filter and coolant. If a coolant flow error (093) occurs after you replace the filter and coolant, use the
troubleshooting procedure in your system’s instruction manual to find the correct action.
The best solution is to follow the usage guidelines for your consumables. However, if overuse occurs, you can replace the
following components more frequently.
Description
Part number
Coolant
028872
HPR quick-disconnect torch receptacle
220163
HPR quick-disconnect torch
220162
Coolant filter element
027664
Kit: Coolant pump with clamp
228170
Coolant check valve
006075
Kit: Coolant flow switch
228022
- HPR130 Manual Gas Preventive Maintenance Program HPR130XD Auto Gas Preventive Maintenance Program Rev.1 HPR130XD Manual Gas Preventive Maintenance Program Rev.1 HPR260 Auto Gas HPR260XD Auto Gas Preventive Maintenance Program Rev.1 HPR260XD Manual Gas Preventive Maintenance Program Rev.1 HPR400XD Auto Gas Preventive Maintenance Program Rev.1 HPR800XD Auto Gas Preventive Maintenance Program Rev.1 HPR400XD Manual Gas Preventive Maintenance Program Rev.1 HPR800XD Manual Gas Preventive Maintenance Program Rev.1