beautypg.com

Desa HD-9260 User Manual

Page 8

background image

-8-

598-1007-02

Finish Mounting

Align the JourneyMan

®

base plate, gasket, and

the junction box holes. Secure with mounting
screws that fit your junction box.

If not installed on a weatherproof box or if the
adaptor plate was used, caulk between the
base plate and mounting surface
with sili-
cone weather sealant.

To obtain maximum lamp
life, keep the tubular
lamps horizontal.

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

Specifications

Range .............................. Up to 100 feet (30.5 m) with

Range Boost On; up to 70
feet (21 m) with Range
Boost Off. (Varies with sur-
rounding temperature).

Sensing Angle ................. Up to 270

°

Fixture Load ................... 500 watts max., Incandescent

(250W each lamp holder)

Sensor Load Capacity ..... 1000 watts (8.3 amps), In-

candescent

Power Requirements ....... 120 VAC, 60 Hz

Operating Modes ............ TEST, AUTO and MANUAL

MODE

Time Delay ..................... 1 , 5, 20 minutes

Sensitivity ....................... Adjustable

CAUTION: To Avoid Fire Or Burn Hazards:

• Allow fixture to cool before touching. The bulb and the fixture

operate at high temperatures.

• Keep fixture at least 3" (76 mm) from combustible materials.

Do not aim at objects closer than 3' (1 m).

• Use only type T 250W (max.) tungsten halogen 120 VAC lamps.