598-1007-02
Finish Mounting
❒
Align the JourneyMan
®
base plate, gasket, and
the junction box holes. Secure with mounting
screws that fit your junction box.
❒
If not installed on a weatherproof box or if the
adaptor plate was used, caulk between the
base plate and mounting surface with sili-
cone weather sealant.
To obtain maximum lamp
life, keep the tubular
lamps horizontal.
;;;;;
;;;;;
;;;;;
;;;;;
;;;;;
;;;;;
;;;;;
;;;;;
Specifications
Range .............................. Up to 100 feet (30.5 m) with
Range Boost On; up to 70
feet (21 m) with Range
Boost Off. (Varies with sur-
rounding temperature).
Sensing Angle ................. Up to 270
°
Fixture Load ................... 500 watts max., Incandescent
(250W each lamp holder)
Sensor Load Capacity ..... 1000 watts (8.3 amps), In-
candescent
Power Requirements ....... 120 VAC, 60 Hz
Operating Modes ............ TEST, AUTO and MANUAL
MODE
Time Delay ..................... 1 , 5, 20 minutes
Sensitivity ....................... Adjustable
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the fixture
operate at high temperatures.
• Keep fixture at least 3" (76 mm) from combustible materials.
Do not aim at objects closer than 3' (1 m).
• Use only type T 250W (max.) tungsten halogen 120 VAC lamps.