beautypg.com

Controlling non-motion sensing fixtures – Desa HD-9260 User Manual

Page 7

background image

-7-

598-1007-02

Controlling Non-Motion Sensing Fixtures

When wiring to additional standard fixture

only: Strip the motion sensor's red wire and
connect to the standard fixture's black wire.
Connect all white wires together. Total fixture
ratings must not exceed 1000W (8.3 A).

NOTE: All wiring between fixtures should be run

in accordance with the National Electrical Code
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.

This fixture is provided with a sensor rated

for 1000W. Since the fixture is only rated 500W,
500W of additional load may be controlled by
this sensor.

When determining what a fixture is rated for,

do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.

Once you have selected the fixtures to be con-

nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100W, 150W, and 75W respec-
tively, you have a total load of 325W.

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

;;;;;

Wiring to a Motion Light & Standard Fixture

Standard

Fixture

RED from JourneyMan

®

to

BLACK from Fixture

BLACK from Switch to

BLACK from JourneyMan

®

WHITE from Line to

WHITE from JourneyMan

®

WHITE from Line to

WHITE from Fixture