Desa SH-5710 User Manual
Motion sensor light control, Operation, Model sh-5710
© 2004 DESA Specialty Products™
598-1163-01
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• Note: This product is not recommended for use where
the outside temperature is below -10
°
F.
Model SH-5710
Light Control
Sensor
Cover Plate
Lamp Holders
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
• Additional energy savings with compact fluorescent
bulbs.
Motion Sensor
Light Control
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Compact
Fluorescent Bulbs
2 Wire
Connectors
This package includes:
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
10 5 1 TEST
10 5 1 TEST
ON-TIME
TEST
... back on.
AUTO
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5, or
10 minute position. Note: Although
the 1 minute mode can be used, the 5
or 10 minute mode is recommended
for best operation and performance
when using compact fluorescent bulbs.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Move ON-TIME Switch
to 1, 5, or 10 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Mode:
On-Time:
Works:
Day
Night
Test
5 Sec
x
x
Auto
1, 5, 10 min.
x
Manual
Until Dawn*
x