Sidewall Propeller Fans

3

Fan

Size

Damper

Size

Square

Recommended Wall Opening (W.O.)

Square

M

Minimum

Filtered Supply Wall Housing Only

Figures 1 and 2

Figure 3

Figure 4

A

B

C

Filter Quantity & Size

8

10 (254)

14

1

4

(362)

10

1

2

(267)

-

6 (152)

-

-

-

-

10

12 (305)

16

1

4

(413)

12

1

2

(318)

-

6 (152)

-

-

-

-

12

14 (356)

19

1

4

(489)

14

1

2

(368)

-

7 (178)

-

-

-

-

14

16 (406)

21

1

4

(540)

16

1

2

(419)

-

8 (203)

-

-

-

-

16

18 (457)

23

1

4

(591)

18

1

2

(470)

-

9 (229)

-

-

-

-

18

20 (508)

25

1

4

(641)

20

1

2

(521)

-

10 (254)

-

-

-

-

20

22 (559)

27

1

4

(692)

22

1

2

(572)

-

12 (305)

-

-

-

-

24

26 (660)

33

3

4

(857)

26

1

2

(673)

33

3

4

(857)

13 (330)

32

1

4

(819)

63 (1600)

24 (610)

4

23

1

4

x 16

1

4

(591 x 413)

30

32 (813)

39

3

4

(1010)

32

1

2

(826)

39

3

4

(1010)

13 (330)

38

1

4

(972)

65 (1651)

26 (660)

4

24

5

8

x 19

1

4

(625 x 489)

36

38 (965)

45

3

4

(1162)

38

1

2

(978)

45

3

4

(1162)

14 (356)

44

1

4

(1124) 67

1

4

(1708)

28

1

4

(718)

6

23

1

4

x 22

1

8

(591 x 562)

42

44 (1118)

51

3

4

(1314)

44

1

2

(1130) 51

3

4

(1314)

15 (381)

50

1

8

(1273) 72

7

8

(1851)

34 (864)

6

24

1

8

x 25

1

8

(613 x 638)

48

50 (1270)

57

3

4

(1467)

50

1

2

(1283) 57

3

4

(1467)

16 (406)

56

1

8

(1426) 72

7

8

(1851)

34 (864)

12 23

1

4

x 18

3

4

(591 x 476)

54

56 (1422)

63

3

4

(1619)

56

1

2

(1435) 63

3

4

(1619)

17 (432)

62

3

8

(1584) 79

11

16

(2024) 40

11

16

(1033) 12 23

1

4

x 20

3

4

(591 x 527)

60

62 (1575)

69

3

4

(1772)

62

1

2

(1588)

-

19 (483)

-

-

-

-

72

74 (1880)

84

3

4

(2153)

74

1

2

(1892)

-

19 (483)

-

-

-

-

All dimensions given in inches

(millimeters). Filters are 2 inch (51 mm) nominal thickness. Above filter sizes are actual dimensions.

W.O.

W.O.

M

W.O.

Filters

Wall
Housing

Filter
Section

INTERIOR

W

all

EXTERIOR

Optional 90º
Weatherhood

Filters

Airflow

Optional
Damper

Wa

ll

A

C

B

24 in.

15 in.

Preinstallation Checks

• Check chart below for correct wall opening

dimensions.

• Check motor voltage and amperage rating for

compatibility with electrical supply. Supply wiring
must be properly fused and conform to local and
national codes.

• Motor load amperage must be checked and

compared to nameplate rating to avoid serious
damage to motor when speed is increased.

Wall Opening Requirements

Wall opening size and propeller-to-damper distance
are two important dimensions for fan installation.

Fans mounted to the wall require a different wall
opening (W.O.) size than those mounted in collars or
wall housings. Propeller-to-damper distance (M) is
important to reduce turbulence and damper flutter
which may lead to premature damper failure.

Figure 1 and 2 show the wall opening (W.O.) required
for installations with either a wall housing or collar.

Figure 3 shows the recommended wall opening (W.O.)
and the minimum distance (M) suggested between the
fan and damper for direct to wall installations.

Figure 4 shows the dimensions and wall opening
(W.O.) required for installations with a filtered supply
wall housing.

Figure 3 - Direct to Wall Installation

Figure 1 - Wall Housing Installation

Figure 2 - Wall Collar Installation

Figure 4 - Filtered Supply Wall Housing Installation

®