Coil dimensions, Continued – Greenheck Modular Small Cabinet Fan (Model MSCF) (462888) User Manual
Page 9

9
Modular Small Cabinet Fan
®
Direct Expansion (DXI) • 4, 6 or 8 Row
Dual Circuit with 50/50 Face Interlaced Construction
NOTE
The first suction header on the entering air side
of the coil is circuited to the top distributor. With
airflow from left to right, the fluid enters the coil
from the center connection (Inlet) and exits from the
bottom (Outlet). The other connections should be
capped off (cap).
Unit
Size
Face
Area
A
B
C
D
E
F
G
4 Row 6 & 8
Row 4 Row 6 Row 8 Row
30
3.2
38 24.5 18.5 9.25
11.0
7.88
8.50
8.5
7.00
12.0
45
4.5
50 24.5 18.5 9.25
11.0
7.88
8.50
8.5
7.00
12.5
50
5.2
50 24.5 21.0 9.25
11.0
7.50
8.50
8.75
7.75
13.5
65
6.7
50 24.5 26.0 9.25
11.0
8.12
8.75
8.75
9.50
17.0
85
8.6
62 24.5 26.0 9.25
11.0
8.12
8.75
8.75
9.50
17.0
All dimensions are in inches.
Coil Dimensions -
continued
Airflow
1
A
B
3
C
Coil connection made inside housing.
Two inch hole is provided.
18.5
E
D
F
G
3.75
6.5
2
1.5
Inlet 1
Inlet 2
(cap) (cap)
13.25
Outlet 1
Outlet 2
- VCD-40 Extension Pin Kit 316SS (475290) (2 pages)
- 331-2856, 332-2856 - Siemens 6 Actuator (454206) (2 pages)
- 331-2976, 332-2976 - Siemens 4 Actuator (454202) (2 pages)
- 331-4551, 332-4551 - Siemens 3 Actuator (454201) (2 pages)
- Adjustable Pressure Controller (468292) (3 pages)
- 7800 Series Relay Modules (12 pages)
- Standard Control - MSSC (476372) (4 pages)
- NFB Series Actuators External Mount (464236 IOM) (2 pages)
- GND Series External Mount (473723) (4 pages)
- Amplifier for 7800 Series Relay Module (8 pages)
- APEX Curbs (462831) (4 pages)
- AMD-xx-TD Transmitter (35 pages)
- Blade Seal Repalcement (HCDR Series) (1 page)
- VCD (463384) (12 pages)
- BAPI Zone Pressure Touch (ZPT) Sensor (6 pages)
- VCD (463384) (10 pages)
- Blade Seal Replacement (HCD Series) (2 pages)
- BR Series - Counterweight Adjustment (469420) (4 pages)
- Leakage Rated Ceiling Radiation Dampers (475063 IOM). (32 pages)
- Canopy Hoods (452413 IOM) (36 pages)
- Clean-Out Port Kit (472428) (1 page)
- Centrifugal (CSW, BIDW, AFDW), Industrial (IPA, IPO, IPW) and Filtered Supply (LSF) (463687) (12 pages)
- Close Indicator Switch for Fire Dampers (474050) (1 page)
- Concrete Floor with Steel Deck Supplement (463562) (1 page)
- CRD-3XX and CRD-7XX Series for SP fans (452832) (2 pages)
- VCD (463384) (4 pages)
- VCD (463384) (8 pages)
- Single Side Retaining Angle (52 pages)
- DG / DGX with Pilot Ignition (463555 IOM) (Pre-2008) (48 pages)
- DG / DGX with Direct Spark (470652) (40 pages)
- Digital Temperature Interlock (474750 IOM) (Pre November 2012) (8 pages)
- DGK (468695) (20 pages)
- DG / DGX with Pilot Ignition (463555 IOM) (Pre-2008) (52 pages)
- Double Gland Axle Seal Replacement (1 page)
- Dock Arm Kit (475367) (4 pages)
- Duct Heaters Series IDHB and IDHC (478052) (8 pages)
- EHH-601D, Channel Installation (474643) (10 pages)
- EHH-601D, Channel Installation with VCD-40 Damper (474644) (8 pages)
- EHH-601D, Flange/Sleeve Installation (474641) (8 pages)
- GM Series (468391) (4 pages)
- EHH-601D, Flange/Sleeve Installation with VCD-40 Damper (474642) (8 pages)
- El-O-Matic E and P Series (12 pages)
- Energy Recovery Filter Hood System (8 pages)
- ERV-582/120 Curbs (460988) (4 pages)
- ESD-635D, Chanel Installation (474639) (10 pages)