beautypg.com

Electrical connections – Greenheck Housed Plenum Array , Plug and Plenum Fans (475405) User Manual

Page 9

background image

9

Housed Plenum Array, Plug and Plenum

Field Coating Touch-Up Procedure

for Scratched Areas

Standard coating is Greenheck’s Concrete Grey,
RAL 7023. The procedure below details the correct
method for repairing minor scratches in the coating.

1. Scuff affected area to be repaired using medium

sandpaper (provided) or medium scotch brite pad.
Feather the edges.

2. Clean affected area to be touched up using an

alkaline based cleaner and rinse.

3. Apply Kem Kromik primer using 1 inch foam brush

(provided). Follow technical data sheet instructions.

4. Allow primer to dry a minimum of 2 1/2 hours before

top coating.

5. Apply topcoat with industrial enamel using 1 inch

foam brush (provided). Follow technical data sheets
instructions. Allow painted units to air-dry and cure
before putting into service. See enclosed Technical
Data sheets for detailed drying and cure schedules
at different temperatures.

To order additional coating repair kits please reference
Greenheck’s part number HAZ2597, PNT FIELD REPAIR
KIT, RAL 7023 CONCRETE GREY kit. Please contact
factory with your fan’s serial number for colors other
than our standard.

TOUCH-UP PAINT REPAIR KIT CONTENTS

• One pint of Kem Kromik primer

- including a technical data sheet

• One pint of industrial enamel

- including a technical data sheet

• Four disposable foam brushes
• One sheet sandpaper
• Repair procedure details

Before electrical connections are made, the supply
voltage, phase and ampere capacity must be checked
for compatibility with the fan motor. In addition, the
supply wiring must be properly fused and conform to
local and national electrical codes. If the unit is supplied
with a safety disconnect switch, ensure proper wiring
to the fan motor. Be sure the disconnect is switched to
the “OFF” position before connecting supply wires. If
no disconnect is supplied, ensure the supply wire is not
live before connection. Supply wires are then connected
to the optional safety disconnect switch (if supplied) or
motor.

Electrical Connections