Adjusting the String Clamp Jaw
Spacing
The string clamps will need minor adjust-
ments according to what string type, con-
struction, and gauge you are using.
To adjust the gap (clamping pressure)
between the clamp jaws, insert the string
through the racquet as if you were beginning
the main strings. Clamp the strings and pull
tension. If the string slips through the jaws of
the clamp, tighten the clamp by squeezing
the clamp jaws together by hand while turn-
ing the Adjustment Knob, in the clockwise
direction. If the clamp leaves impressions
or damages the string, it may be excessively tight and should be adjusted by turning the
Adjustment Knob counter clockwise to open the gap between the jaws.
NOTE: Due to the bearings used in the Clamp Lever the action of the Clamp Lever is
very light making it easy to apply excessive clamping pressure. Clamps that are set
too tight can damage the string as well as the string clamp jaws.
The clamp jaws should be cleaned periodically to be free from dirt, oil, and any string coating
residue to grip properly. Knife sharpening stones are excellent for removing build-up on the
diamond coated surfaces and are available.
Quick Action Clamp Base Removal
Quick Action clamp bases can be removed
from the turntable for maintenance or cleaning
by removing clamp stop located at the end
of the slot in the turntable. To remove the
clamp stop, remove the two screws holding
the clamp stop in place from the underside of
the turntable. Lift the clamp stop out of the
slot, slide the clamp base to the end of the
slot and lift it out. Replace the clamp base
and clamp stop in reverse order.
Adjusting the Clamp Base Locking
Nut
In the event the Locking Lever rotation is
insuffi cient to ensure smooth operation of the
clamp base, very minor adjustments to the
Clamp Base Locking Nut can be made with
the supplied 17mm socket wrench. Tighten
or loosen the locking nut in very small incre-
ments to provide more clamping pressure or
running clearance as needed.
MAINTENANCE & ADJUSTMENT
Adjustment
Knob
- 5003 STRINGING MACHINE 6 POINT SC MOUNTING (Issue 10A - Febryary 2014) 5003 STRINGING MACHINE 6 POINT SC MOUNTING (Issue 4A - February 2014) 5003 STRINGING MACHINE 2 POINT SC MOUNTING (Issue 2 - December 2009) 5003 STRINGING MACHINE 6 POINT SC MOUNTING (Issue 1 - April 2010) PROGRESSION STII STRINGING MACHINE (Issue 7A - February 2014) 6004 STRINGING MACHINE 2 POINT SC MOUNTING (Issue 3 - September 2010) 5003 STRINGING MACHINE 2 POINT SC MOUNTING (Issue 3 - August 2010) 6004 STRINGING MACHINE 2 POINT SC MOUNTING (Issue 5C - February 2014) 5003 Els STRINGING MACHINE 6 POINT SC MOUNTING (Issue 7 - December 2009)