Error

message

Description

Possible error

reason

Troubleshooting

Er36

NTC value is not
within its
specification
(value < 200mV or
> 4.9V; control unit
cuts off

Short-circuit or
cut-off at
NTC

Exchange control
unit

Er31

Configuration data
incorrect

Configuration of
induction
necessary

New
Configuration

Er47

Communication
error between
TC and induction

None or faulty
communication!

Ensure that
connection cable
is plugged on
correctly and
functional.

E2

Overheating of the
induction coils

Cooling down
necessary

U400

Secondary voltage
of the power unit
to high (primary >
300V). Control unit
cuts off after 1 sec
releasing a
permanent tone.

Control unit is
wrongly
connected.

Connect to
correct mains
voltage

E5

Error on filter
board

Exchange filter
board

E6

Error on power
unit

Exchange power
unit

E9

Coil temperature
sensor
defective

Exchange
temperature
sensore