beautypg.com

Technical data – Fronius String Control 250/30 User Manual

Page 43

background image

41

EN

Technical data

Technical data

max. input voltage in open circuit

1000 VDC

max. input current

250 A

max. input current per fuse holder

20 A

max. number of strings (with integral solar module fuse)

30

max. conductor cross-section for terminals on the DC side

single-wire cable cross-section

multi-strand cable cross section

2.5 - 25 mm

2

2.0 - 16 mm

2

max. conductor cross-section for the M12 connections on the
inverter side

240 mm²

number of measuring channels

5

max. current per measuring channel

50 A

screw joint for fixing cables on the solar module side

M32

with 3-way sealing glands

screw joint for fixing cables on the inverter side

M40

EMC emissions class

A

degree of protection

IP 55

protection class

II

environmental conditions

-25 °C - +55 °C

-13 °F - +131 °F

dimensions (excluding screw joints)

720 x 580 x 200 mm

28.3 x 22.8 x 7.9 in.

Fronius DATCOM power supply

via Fronius Solar Net

optional via 12 V DIN rail power pack

max. power consumption for Fronius Solar Net

110 mA

Weight

16.3 kg

36 lbs.