6. MAINTENANCE

6.1 Cleaning

How often the FD 260-10 needs cleaning depends on
the amount of paper dust your mail pieces generate.
Wipe surface dust or debris from the FD 260-10 with
a damp cloth as necessary.

6.2 Replacing A

Static Brush

Inspect the static brush regularly for wear on the
bristles. The static brush is located at the output end
of the FD 260-10. When some bristles wear to half
their original length, the static brush must be
replaced. The bristles will most likely not wear
evenly. Compare the worn bristles to unworn bristles
(on the outside edges). Contact an authorized
Formax dealer to replace your static brush.

WARNING

WORN BRISTLES ON THE STATIC BRUSH MAY

CAUSE STATIC ELECTRICITY BUILD-UP WHICH

COULD SHOCK THE OPERATOR AND DAMAGE

EQUIPMENT.

6.3 Replacing A

Fuse

To replace a blown fuse (refer to Figure 6.1):

CAUTION

VERIFY THAT THE LINE FUSE VALUE IS

CORRECT FOR THE VOLTAGE SETTING.

UNPLUG THE FD 260-10 BEFORE STARTING

THIS PROCEDURE.


1. Unplug the POWER CORD.

2. Use a small screwdriver or similar tool to push up

on and release the FUSE DRAWER LOCKING
TAB.