Power connection – Formax FD 260-10 User Manual
Page 12
8
3. POWER CONNECTION
WARNING
BEFORE PLUGGING THE FD 260-10 INTO AN
OUTLET, CAREFULLY READ THE FOLLOWING
INFORMATION ABOUT VOLTAGES, FUSES AND
THE POWER CORD.
3.1 Safety
The FD 260-10 can connect to any power distribution
system, including the European IT Power System.
Because the European IT Power System does not
have a grounded neutral leg, the FD 260-10 uses
protective fusing in both the neutral and hot supply
lines of power.
WARNING
A BLOWN FUSE IN THE NEUTRAL LEG COULD
MEAN INTERIOR PARTS OF THE FD 260-10
REMAIN AT A HAZARDOUS VOLTAGE. ALWAYS
UNPLUG THE POWER CORD BEFORE REMOVING
COVERS FROM THE FD 260-10.
3.2 Line Voltage
The FD 260-10 is rated for continuous operation
using a variety of supply voltages. Possible line
voltages are 240V, 230V, 220V, 120V and 100V at 50
or 60 Hz. The manufacturer configures the FD 260-
10 to operate with the voltage requested by the
customer.
CAUTION
VERIFY THE CORRECT VOLTAGE SETTING
BEFORE PLUGGING THE FD 260-10 INTO AN
OUTLET.
Read the current voltage setting through the
VOLTAGE SELECTOR WINDOW on the input end of
the FD 260-10 (refer to Figure 3.1). Use the
following instructions to change the voltage setting: