Side Gauge with Scale

Measurement in mm/cm and inches. The indicator on the back-gauge will point out the current

measurement. The fine adjustment can be done via the scale ring. The minimum adjustment is 0.5mm.

Stand

The standard equipment of WKH&XW7UXH 22S is made of steel.

Overload lamp

The overload protection device will turn off the power automatically while unusual heavy loading occurs.

A blunt blade may cause the overload protection to shut down the machine.

Power Switch

2 enable switches

3 socket headless screws for adjusting the balance of the blade after changing to

a new blade.
Functional hole for lifting up the cutting stick

Fine adjustment device for the blade

The scale is only 0.2 mm. Turn it clockwise to raise the blade up.

Back-gauge Crank

Pull the back-gauge crank toward the operator in order to make it idle and to avoid the measure moving

forward or backward.

Digital Measurement readout

It can be switched over from cm to inches and vice versa. This function is only on WKH&XW7UXH6