beautypg.com

Englis h – Formax FD 6102 User Manual

Page 24

background image

23

ENGLIS

H

6.3.2

Envelope Sealing Problems

Symptom

Possible cause

Remedy

Reference

Envelope not
closed properly.

Insufficient
moistening.

See symptom “Flap not
sufficiently moistened.”
on page 23.

The current job has
no envelope sealing.

Make sure if the job
is programmed to
seal envelopes.

“Job Programming” on
page 17

Document or
enclosure not
compliant with job
specification.

Make sure the
document size and
enclosure size equals
the job settings.

Documents are not
correctly inserted.

Make sure the side
guides of the
document feeders
are in the correct
position.

“Adjusting the Side
Guides of the Document
Feeder” on page 13

Check envelope stop
position, adjust if
needed.

“Envelope Position” on
page 26

Envelope contents
is wet.

Sealing position is
not correctly set.

In the supervisor
menu change the
settings of the
applicable envelope.

“Sealing position” on
page 26

Exit roller is wet.

Clean the exit roller. “Clean the System” on

page 19

Flap not
sufficiently
moistened.

Water level low.

Check water level,
refill if needed.

“Filling the Sealing
Liquid Reservoir” on
page 15

Brushes dry.

Check brushes,
replace if needed by
the extra soaked set.

“Operator Maintenance”
on page 19

Brushes dirty.

Check brushes, clean
if needed.

“Operator Maintenance”
on page 19

Brushes worn out.

Replace brushes.

“Operator Maintenance”
on page 19

The current job has
no envelope sealing.

Choose job with
envelope sealing.

Envelope does not
meet the
specifications.

Make sure the
envelope meets the
specifications.

“Envelope and Insert
Specifications” on
page 28

Poor envelope
quality.

Seal an envelope
manually to test the
adhesion quality.

Sealing position is
not correctly set.

In the supervisor
menu change the
envelope settings.