TROUBLESHOOTING

TROUBLE

POSSIBLE CAUSE

REMEDY

Control panel lights are

not illuminated.

No power at the wall outlet.

No power to the machine inlet.

No power to the control panel.

Internal electrical failure

Check wall outlet.

Check power cord for frayed/broken

wires.

Press the black breaker reset button

located on the backside of the sealer,

see pg. 12 Fig. 17.

Call for service

Fold plate stop not

moving when “Fold

Setup” is pressed.

Fold plate is not plugged in.

Electrical or mechanical failure

Plug fold plate in.

Call for service.

Sealer does not turn on

when the form enters

the throat of the sealer

transport deck.

Sealer is not turned on

Sealer reset button has not

been pressed after a paper jam

Sealer breaker has popped

Photo eye is not detecting the

form

Check that the sealer is plugged in and

turned to the on position.

Press the “counter reset” button to reset

the sealer

Press the black breaker reset button

located on the backside of the sealer,

see pg. 12 Fig. 17.

Wipe sensor with dry cloth.

Call for service

Standard fold is

misfolding

Fold plate is not plugged in.

Wrong fold is selected

Fold plates are not inserted

correctly.

Piece of paper or other material

is stuck in the fold plate.

Plug fold plate in.

Check to make sure the correct fold is

selected from the “Standard fold menu”

A custom fold may need to be created

if the fold varies from the standard fold

setting, see pg 9 for custom fold setup.

Remove and reinstall fold plates. Be

sure they’re properly positioned.

Remove object from the fold plate.