Dell POWEREDGE R710 User Manual
Page 34
Dell™ PowerEdge™ R710 Technical Guidebook
34
Dell™ PowerEdge™ R710 Technical Guidebook
POWeReDGe R710
PCI Express Gen2 Slots
Slot 1: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Slot 2: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width
Slot 3: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width
Slot 4: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Slot 5: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width
Category
Card
Priority
Description
Dell PN PCIe Link
Width
Slot
Priority
Max
Cards
Internal Storage
(Integrated Slot)
1
Dell™ PERC 6/i Integrated (Sled)
T95
4J
Gen1 x8
Integrated
1
Internal Storage
(Integrated Slot)
2
Dell SAS 6/iR Integrated (Sled)
YK8
38
Gen1 x8
Integrated
1
External Storage
Controller
3
*Dell PERC 5/E Adapter
(Test only, no factory install)
GP2
97
Gen1 x8
Slot 4, 5
1
2
2
External Storage
Controller
4
*Dell PERC 6/E Adapter
(512MB)
J15 5F
Gen1 x8
Slot 3, 2,
5, 4, 1
2
2
External Storage
Controller
5
*Dell PERC 6/E Adapter
(256MB)
F98
9F
Gen1 x8
Slot 3, 2,
5, 4, 1
2
2
10Gb NIC
6
*Intel 10GBase-T Copper Single
Port NIC (Copperpond)
XR9
97
Gen1 x8
Slot 4, 5, 1,
2, 3
2
10Gb NIC
7
*Broadcom BCM57710
10GBase-T Copper Single Port
NIC (Quiver)
RK3
75
Gen1 x8
Slot 4, 5, 1,
2, 3
2
10Gb NIC
8
Intel
®
10GBase-SR Optical
Single Port NIC (BelleFontaine)
RN
219
Gen1 x8
Slot 4, 5, 1,
2, 3
2
External Storage
Controller
9
*Dell SAS 5/E Adapter
M7
78G
Gen1 x8
Slot 3, 2,
4, 5, 1
2
2
Internal Tape
Controller
10
Dell SAS 5/iR Adapter
(for internal tape only)
UN
939
Gen1 x8
Slot 3, 2,
4, 5, 1
2
2
Fibre Channel
8 HBA
11
Emulex LPe12002 FC8
Dual-Channel HBA
C85
6M
Gen2 x4
Slot 4, 5, 1,
2, 3
5
Fibre Channel
8 HBA
12
Emulex LPe12000 FC8
Single-Channel HBA
C85
5M
Gen2 x4
Slot 4, 5, 1,
2, 3
5
1
Thermal testing to determine if the PERC5 can be installed in other slots is pending.
2
A maximum of 2 nternal/external storage controllers (Dell PERC and SAS cards) are allowed in the system in addition to the integrated storage controller.